Water Saturation Pressure Formula Comparison

Compare liquid-water and ice saturation-pressure fits across a bounded temperature range.

  • Formula & worked example
  • Private in your browser
  • No signup
Go to tool

Calculator inputs

Loading calculator…

How to use this calculator

  1. Enter the known values in the units shown. Results update as you type.
  2. Where results are editable, change one to solve backwards. Lock a value to hold it fixed.
  3. Use the worked example to check the method. Reset restores the starting fields.

Private by default

Inputs and results stay in this browser tab. Bookify does not upload or store the values you enter.

Formula and method

At 0 °C, the Magnus, Tetens and Buck liquid estimates are 0.61094, 0.61078 and 0.61121 kPa, respectively.

Liquid fits: Antoine, Magnus, Tetens, Buck and a simplified exponential; ice fits: Tetens and Buck.

Worked example

Enter these known values and leave the other values blank.

Temperature
0 °C
Simplified formula
0.6521 kPa
Antoine liquid fit, 0–100 °C
0.6056 kPa
Magnus formula
0.611 kPa
Tetens formula
0.6108 kPa
Buck formula
0.6112 kPa

Assumptions and limitations

  • The supported range is −80 to 200 °C. Displayed formula branches retain their individual domains: ice below zero, liquid at or above zero, and the second Antoine coefficient set above 100 °C.
  • These are empirical approximations with different fitted ranges and uncertainties. Display does not establish equal accuracy at every temperature in the overall range.
  • Saturation pressure is a phase-equilibrium property, not current humidity or total atmospheric pressure. Water and ice fits differ.
  • Antoine and the simplified exponential calculate mmHg internally; other fits calculate kPa. Display conversions must be compared in the same pressure unit.
  • The Buck and ice Tetens source equations use 2.718281828459 as their rounded exponential base. This historical precision is retained.

Common questions

Why do the formulas disagree?

Their fitted coefficients, phase assumptions and valid experimental ranges differ.

Does this give humidity?

No. Actual vapor partial pressure is needed to calculate relative humidity.

References

Declare the physical or stated approximation domain; captured arithmetic is unchanged.

Explore chemical thermodynamics calculators 🌡️ or browse all chemistry calculators.