Free · Physics models

RMS Apparent and Real Electrical Power

Relate RMS voltage, current, apparent power and power factor for one or three phases.

  • Formula & worked example
  • Private in your browser
  • No signup
Go to tool

Calculator inputs

Loading calculator…

How to use this calculator

  1. Enter the known values in the units shown. Results update as you type.
  2. Where results are editable, change one to solve backwards. Lock a value to hold it fixed.
  3. Use the worked example to check the method. Reset restores the starting fields.

Private by default

Inputs and results stay in this browser tab. Bookify does not upload or store the values you enter.

Formula and method

kva1P = 2.4000; realPower 1P = 1.9200. This worked example uses the displayed units and declared assumptions.

kva1P = current * voltage / 1000; powerFactor = realPower_1P / kva1P; kva3Pll = sqrt(3) * current * voltage / 1000; powerFactor = realPower_3Pll / kva3Pll; kva3Pln = 3 * current * voltage / 1000; powerFactor = realPower_3Pln / kva3Pln

Worked example

Enter these known values and leave the other values blank.

Load distribution
0
Current (I)
10 A
Voltage (V)
240 V
Power factor
0.8
Apparent power (S)
2.4 kVA
Real power (P)
1.92 kW

Assumptions and limitations

  • Three-phase relations assume balanced sinusoidal loads. Select line-to-line or line-to-neutral voltage consistently. Real power is apparent power multiplied by power factor, with no motor or generator efficiency correction.
  • Clear an unknown to solve a supported inverse; keep known values fixed with locks. Singular or underdetermined inverses may remain incomplete.

Common questions

What assumptions apply?

Three-phase relations assume balanced sinusoidal loads. Select line-to-line or line-to-neutral voltage consistently. Real power is apparent power multiplied by power factor, with no motor or generator efficiency correction.

Which unknowns can I solve?

Editable controls preserve the supported captured inverse branches. Clear the desired unknown and provide enough independent known quantities; singular or underdetermined inverses may remain incomplete.

References

Use positive RMS voltage for the finite power-factor inverse. Use positive RMS current for the finite power-factor inverse. Replace example-note option accessors by their pinned numeric selector values, preserving the exact visibility predicates.

Explore physics models or browse all physics calculators.