Boundary-Mode Flyback Transformer Estimate

Calculate ideal duty, peak winding currents and referred inductances at the discontinuous-conduction boundary.

  • Formula & worked example
  • Private in your browser
  • No signup
Go to tool

Calculator inputs

Loading calculator…

How to use this calculator

  1. Enter the known values in the units shown. Results update as you type.
  2. Where results are editable, change one to solve backwards. Lock a value to hold it fixed.
  3. Use the worked example to check the method. Reset restores the starting fields.

Private by default

Inputs and results stay in this browser tab. Bookify does not upload or store the values you enter.

Formula and method

At the boundary with 20 V input, 9 V output, 1 V rectifier drop, 1 A output and 100 kHz switching, a 2:1 transformer gives 50% duty and 50 µH primary inductance.

D = n (Vout + Vrect)/(Vin + n (Vout + Vrect)); Is,pk = 2 Iout/(1 − D).

Worked example

Enter these known values and leave the other values blank.

Input voltage (**V==in==**)
20 V
Output voltage (**V==out==**)
9 V
Voltage on the rectifier (**V==rect==**)
1 V
Output current (**I==out==**)
1 A
Switching frequency (**f==s==**)
100 kHz
Windings ratio (**N**)
2
Duty cycle (**D**)
50 %
Peak current on the secondary side (**I==s,Peak==**)
4 A
Inductance on the secondary side (**L==s==**)
12.5 μH
Peak current on the primary side (**I==p,Peak==**)
2 A
Inductance on the primary side (**L==p==**)
50 μH

Assumptions and limitations

  • Peak currents assume triangular pulses with no idle interval: the boundary between continuous and discontinuous conduction.
  • Inductance scales as the square of the turns ratio. Leakage, saturation, switching loss and current ripple in continuous operation are omitted.
  • Enter known quantities and clear the unknown to use available inverse branches. Locks retain supplied values. Consistency messages cover fully visible equations; identities with hidden dependencies may require a manual consistency check. Preset values are illustrative approximations, and unit selectors preserve the underlying quantity.
  • The secondary-inductance inverse selects the physical minus-square-root duty branch, correcting the captured root above 100% duty.

Common questions

Why is secondary peak current more than output current?

Only the off-time pulse supplies the output; its triangular average is half its peak over that interval.

How do I solve for a different quantity?

Clear that quantity and supply enough independent known values. Some outputs are one-way or tied to a selected preset, so they cannot determine every input.

References

The secondary-inductance inverse must use the root D = 1 − sqrt(2 Iout f Ls/(Vout + Vrect)); the captured plus root always exceeds one and violates the physical duty domain. Explicit physical duty domain accompanies the corrected secondary-inductance inverse root.

Explore physics models or browse all physics calculators.