Free · Energy and power converters ⚡
Energy Units and Quantum Equivalents
Convert joules, watt-hours, thermochemical calories, EC therms and TNT equivalents, plus electronvolts, spectroscopic wavenumber, equivalent absolute-temperature scale and mass energy.
- Formula & worked example
- Private in your browser
- No signup
Calculator inputs
Loading calculator…
How to use this calculator
- Enter the known values in the units shown. Results update as you type.
- Where results are editable, change one to solve backwards. Lock a value to hold it fixed.
- Use the worked example to check the method. Reset restores the starting fields.
Private by default
Inputs and results stay in this browser tab. Bookify does not upload or store the values you enter.
Formula and method
One electronvolt is exactly 1.602176634 × 10⁻¹⁹ joules. Its E/kB scale is about 11,604.52 K and its photon wavenumber is about 8,065.54 per centimeter.
E = e × electronvolts; E = kB T; E = hc × wavenumber; E = mc²; 1 Wh = 3600 J; 1 cal(th) = 4.184 J
Worked example
Enter these known values and leave the other values blank.
- Electronvolts
- 1 eV
- Energy
- 1.6022e-19 J
- Thermochemical calories
- 3.829e-23 kcal
- Watt-hours
- 4.4505e-26 kWh
- EC therms (105,506,000 J each)
- 1.52e-27 therms
- TNT tons (4.184 GJ each)
- 3.83e-29 tons of TNT
- Equivalent absolute-temperature scale E/kB
- 11605 K
- Spectroscopic wavenumber
- 8065.5 cm ⁻¹
- Equivalent mass E/c²
- 0.000001957 me
Assumptions and limitations
- Enter one nonnegative energy measure. All nine rows represent the same energy; they are alternatives rather than quantities to add. Zero is accepted. Leave other measurements empty when solving from one value.
- The exact modern SI values are h = 6.62607015e−34 J·s, kB = 1.380649e−23 J/K, e = 1.602176634e−19 C and c = 299792458 m/s. Bookify replaces dated captured equation constants with these definitions.
- The reciprocal-length row is wavenumber: use 1/cm or 1/m, not a wavelength. For a vacuum photon E = hc times wavenumber. The equivalent temperature is E/kB and does not describe an arbitrary material sample’s measured temperature or heat capacity.
- The mass row is the E/c² equivalent, not a conversion between an arbitrary sample’s total mass and its available thermal energy. Electron/proton/neutron/atomic mass units use CODATA 2022 central values with experimental uncertainty. Their displayed digits are not exact definitions.
- This therm is the EC therm at 105,506,000 J, distinct from the US therm at 105,480,400 J. Calories are thermochemical; one nutrition Calorie is one kilocalorie on that convention. TNT tons express conventional energy, not the measured output of an explosive charge.
- Celsius and Fahrenheit selectors are offset representations of the same equivalent absolute scale; values below absolute zero are rejected. Unit conversion precision does not supply physical measurement accuracy.
Common questions
Is reciprocal length a wavelength?
No. It is spectroscopic wavenumber, the reciprocal of wavelength. The displayed 1/cm or 1/m selection determines the reciprocal unit; E = hc times wavenumber for a vacuum photon.
Does the Kelvin result predict a sample’s actual temperature?
It is the energy scale E/kB. A sample’s temperature change also depends on particle count, heat capacity, phase and other physical properties, which this model does not use.
Are all particle-mass conversion factors exact?
No. Electron, proton, neutron and atomic mass-unit factors are CODATA 2022 measured central values. They carry experimental uncertainty, unlike the exact h, kB, e and c definitions.
References
- NIST: current CODATA 2022 constants
- NIST: energy conventions and unit factors
- Calculation definition and unit reference
Modern SI h, kB and electron charge replace dated equation constants; particle mass selectors use CODATA 2022 central values with uncertainty. Energy equivalents are nonnegative; therm is EC and calorie is thermochemical. Use CODATA 2022 central values for electron, proton, neutron and atomic mass units, including the default electron-mass selector. These measured factors carry experimental uncertainty. Require nonnegative energy, photon wavenumber, E/kB absolute scale and E/c² equivalent mass; zero is a valid boundary.
Related calculators
Explore energy and power converters ⚡ or browse all conversion calculators.