Ideal Electrostatic Screening Length

Estimate plasma or electrolyte Debye length from temperature and number density or ionic strength.

  • Formula & worked example
  • Private in your browser
  • No signup
Go to tool

Calculator inputs

Loading calculator…

How to use this calculator

  1. Enter the known values in the units shown. Results update as you type.
  2. Where results are editable, change one to solve backwards. Lock a value to hold it fixed.
  3. Use the worked example to check the method. Reset restores the starting fields.

Private by default

Inputs and results stay in this browser tab. Bookify does not upload or store the values you enter.

Formula and method

Debye length = 0.0011953. This worked example uses the displayed units and declared assumptions.

Debye_length = one_way(sqrt(permittivity_0 * boltzmann_cte * temperature/(electron_density * electron_charge^2))); Debye_length_ev = one_way(sqrt(permittivity_0 * temperature_ev/(electron_density * electron_charge))); Dl_electrolyte = one_way(sqrt(permittivity_r * permittivity_0 * boltzmann_cte * temperature_electro/(2 * ionic_strength * electron_charge^2 * mol_n)))

Worked example

Enter these known values and leave the other values blank.

Medium to compute the Debye length
0
Choose the units for temperature
0
Temperature
300 K
Electron density
1000000000000000000 electrons / m³
Debye length
0.0011953 mm

Assumptions and limitations

  • Linearized weak-coupling, equilibrium Debye screening is assumed. Plasma uses electron density per cubic meter; electrolyte ionic strength is mol/L. The retained vacuum permittivity and 6.02e26 per-m³ molarity conversion are rounded references.
  • Clear an unknown to solve a supported inverse; keep known values fixed with locks. Singular or underdetermined inverses may remain incomplete.

Common questions

What assumptions apply?

Linearized weak-coupling, equilibrium Debye screening is assumed. Plasma uses electron density per cubic meter; electrolyte ionic strength is mol/L. The retained vacuum permittivity and 6.02e26 per-m³ molarity conversion are rounded references.

Which unknowns can I solve?

Editable controls preserve the supported captured inverse branches. Clear the desired unknown and provide enough independent known quantities; singular or underdetermined inverses may remain incomplete.

References

Linearized weak-coupling, equilibrium Debye screening is assumed. Plasma uses electron density per cubic meter; electrolyte ionic strength is mol/L. The retained vacuum permittivity and 6.02e26 per-m³ molarity conversion are rounded references. Clear an unknown to solve a supported inverse; keep known values fixed with locks. Singular or underdetermined inverses may remain incomplete.

Explore physics models or browse all physics calculators.