Signed Hall Coefficient from Measurements

Calculate a signed Hall coefficient from voltage, sample thickness, current and perpendicular magnetic field, retaining inverse measurement calculations.

  • Formula & worked example
  • Private in your browser
  • No signup
Go to tool

Calculator inputs

Loading calculator…

How to use this calculator

  1. Enter the known values in the units shown. Results update as you type.
  2. Where results are editable, change one to solve backwards. Lock a value to hold it fixed.
  3. Use the worked example to check the method. Reset restores the starting fields.

Private by default

Inputs and results stay in this browser tab. Bookify does not upload or store the values you enter.

Formula and method

For Hall voltage 2 mV, thickness 1 mm, current 0.5 A and perpendicular field 0.2 T, the coefficient is 20,000 mm³/C, equivalent to 2 × 10⁻⁵ m³/C.

RH = VH t/(I B). The displayed coefficient is in mm³/C, so multiply its SI value by 10⁹.

Worked example

Enter these known values and leave the other values blank.

Signed Hall voltage
2 mV
Sample thickness along the field
1 mm
Signed measurement current
0.5 A
Signed perpendicular magnetic field
0.2 T
Signed Hall coefficient
20000 mm³/C

Assumptions and limitations

  • This relation assumes a uniform rectangular sample, transverse Hall voltage and magnetic field perpendicular to the current. Thickness is the sample dimension along the field.
  • The coefficient control uses mm³/C. Divide its displayed value by 10⁹ to obtain m³/C; it is a volume-per-charge coefficient, not resistance.
  • Keep the voltage, current and field sign conventions consistent. Reversing one of these measured signs reverses the inferred coefficient; thickness stays strictly positive.
  • Current and field must be nonzero to infer a coefficient. Zero voltage and zero coefficient are valid algebraic values, but do not uniquely determine every inverse quantity.
  • The result does not identify material composition or establish a single-carrier density. Multiple carrier populations, geometry and measurement offsets can complicate interpretation.
  • All five controls remain editable. A missing quantity is filled only when its inverse has enough information and a finite result.

Common questions

Why can the coefficient be negative?

Its sign depends on the Hall-voltage convention and the signed current and field. Use a consistent orientation when interpreting carrier polarity.

Is the result in m³/C?

The retained control displays mm³/C. Divide by one billion for m³/C.

Can I measure it with zero magnetic field?

No. This coefficient relation divides by field and current; both must be nonzero.

References

Thickness must be strictly positive; signed measurement current and perpendicular field must be nonzero. Preserve signed voltage and coefficient, including zero, and the captured mm³/C coefficient scale.

Explore electromagnetism calculators 🧲 or browse all physics calculators.